![Baxi Solo 2 30 RS Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/baxi/solo-2-30-rs/solo-2-30-rs_installation-and-servicing-instructions_2711921006.webp)
TECHNICAL DATA
30 RS
40 RS
Heat Input
Max
Min
kW
11.00
7.69
Btu/h
37,500
26,250
Heat Output
Max
Min
kW
8.79
6.15
Btu/h
30,000
21,000
Burner Pressure
Max
Min
mbar
15.4 + 0.5
8.0 + 0.5
in wg
6.2 + 0.2
3.2 + 0.2
Gas Connection
RC
1
/
2
(
1
/
2
in BSPT)
Electrical Supply
230V~50Hz
fused 3A
Controls
on/off boiler thermostat
with pilot/thermocouple
cut
out/overheat
thermostat on fully
pumped applications only
Heat Exchanger
cast iron monobloc
Lifting Weight
37.3 kg (82.1 lbs)
Water Content
2.1 litres (0.46 gals)
Static Head
Max
Min
metres
30
1
feet
100
3.25
Low Head
Min 0.15m (6in)
System Design
gravity hot water fully
pumped open vented
and sealed systems
Connections
2 x 22mm and a kit for
gravity
Gas Rate
(after 10 mins)
1.05m
3
/h (37.0ft
3
/h)
Outercase
Height
600mm
Dimensions
Width
420mm
Depth
287mm
Flue Terminal
Height
208mm
Dimensions
Width
293mm
Depth
173mm
Heat Input
Max
Min
kW
14.65
11.36
Btu/h
50,000
38,750
Heat Output
Max
Min
kW
11.72
9.09
Btu/h
40,000
31,000
Burner Pressure
Max
Min
mbar
16.3 + 0.5
10.3 + 0.5
in wg
6.5 + 0.2
4.1 + 0.2
Gas Connection
RC
1
/
2
(
1
/
2
in BSPT)
Electrical Supply
230V~50Hz
fused 3A
Controls
on/off boiler thermostat
with pilot/thermocouple
cut
out/overheat
thermostat on fully
pumped applications only
Heat Exchanger
cast iron monobloc
Lifting Weight
37.3 kg (82.1 lbs)
Water Content
2.1 litres (0.46 gals)
Static Head
Max
Min
metres
30
1
feet
100
3.25
Low Head
Min 0.15m (6in)
System Design
gravity hot water fully
pumped open vented
and sealed systems
Connections
2 x 22mm and a kit for
gravity
Gas Rate
(after 10 mins)
1.40m
3
/h (49.3ft
3
/h)
Outercase
Height
600mm
Dimensions
Width
420mm
Depth
287mm
Flue Terminal
Height
208mm
Dimensions
Width
293mm
Depth
173mm
50
50
5
5
300
80
for
ravity
for
servicing
5
inside
cupboard
Clearances
50
50
5
5
300
80
for
ravity
for
servicing
5
inside
cupboard
Clearances
NOTE: On gravity applications a clearance
of 80mm (3
1
/
8
in) is required from the top
panel
NOTE: On gravity applications a clearance
of 80mm (3
1
/
8
in) is required from the top
panel
6