INSTRUCTIONS FOR FITTERS
71.05086.02 - EN
21. PARAMETERS SETTING
•
To scroll the parameters use the b/-
;
• To change the single parameter value use the b/-
;
N.B.:
the value is automatically saved after about 3 seconds. (Do not press any key until the value starts to blink.)
To set the boiler parameters proceed as follows:
• hold down the button
IP
for at least three seconds;
• press and hold down the button
and then press
(see figure at the side).
When the function is active, the letters “
F01
” and the value of the selected parameter appear on the display.
Modifying parameters
0607_1908
Parameter description
Factory settings
280 Fi
F01
Type of boiler
10
= sealed chamber -
20
= atmospheric chamber
10
F02
Gas used
00
=NATURAL (METHANE) -
01
=LPG
00 o 01
F03
Hydraulic system
06
F04
Programmable relay 1 setting
02
=zone system (See SERVICE Instructions)
02
F05
Programmable relay 2 setting
13
=“cool” function for external conditioning system
(See SERVICE Instructions)
04
F06
External probe input configuration
(See SERVICE Instructions)
00
F07…F09
Manufacturer information
Climate controller installation method
00
F10
00
= on the wall (section 18.2)
01
= Not used.
02
= in the boiler (section 18.1)
00
F11…F12
Manufacturer information
00
F13
Max. heating output
(0-100%)
100
F14
Max DHW output
(0-100%)
100
F15
Min. heating output
(0-100%)
00
F16
Maximum heating setpoint setting (°C)
00
= 85°C -
01
= 45°C
00
F17
Pump overrun time in heating mode
(01-240 minutes)
03
F18
Burner ignition delay in heating mode
(00-10 minutes) - 00=10 seconds
03
F19
Manufacturer information
07
F20
Manufacturer information
00
F21
Anti-legionellosis function
00
= Disabled -
01
= Enabled
00
F22
Manufacturer information
00
F23
Maximum DHW setpoint temperature (ACS)
65
F24
Manufacturer information
35
F25
No water safety device
01
F26…F29
Manufacturer information (read-only parameters)
--
F30
Manufacturer information
10
F31
Manufacturer information
00
F32…F41
Diagnostics (See SERVICE Instructions)
--
Final
parameter
Calibration function activation
(See SERVICE Instructions)
0
Attention:
do not modify the values of the “Manufacturer information” parameters