17.0 Fault Finding
Fault Finding Solutions Sections
Is there 230V at:
Main terminals L and N
Check electrical supply
1.
NO
Main terminal fuse
Replace fuse
Replace PCB
Display
illuminated
2.
NO
PCB - X1 connector
terminals 1,2
Check wiring
3.
NO
NO
A
CH system pressure less than 0.5 bar
Re-pressurise system
1.
YES
Check the tap of the automatic air
vent is opened
Open the automatic air vent
2.
NO
C
1.
NO
YES
Fan connections correct at fan. PCB -
X2 connector, is 230V AC across
terminals 5 & 7
Fan jammed or faulty winding
Replace PCB
Replace fan
YES
D
NO
Replace water
pressure switch
Check connection water pressure
switch terminal
COM - NO and PCB connector
X400 terminals 3,4
YES
Is there 230V at:
X3 Connection Pump PCB
1.
NO
YES
B
Check incoming wiring
X2 Connection Pump PCB
NO
Replace Pump PCB
YES
X1 Control PCB
NO
Check wiring
YES
X3 Control PCB, T3, T4
NO
Replace Control PCB
YES
X1 Pump PCB
NO
Replace Pump PCB
YES
Replace Pump