4.0 Technical Data
7
Flue Terminal
Diameter
100mm
Dimensions
Projection
93mm
Outercase Dimensions
Casing Height
-
950mm
Overall Height Inc Flue
-
1080mm
Casing Width
-
600mm
Casing Depth
-
450mm
Clearances
LH Side
20mm Min
RH Side
5mm Min
Above Casing
200mm Min
Below Casing
250mm Min
Front
450mm Min
(For Servicing)
Front
5mm Min
(In Operation)
Weights
kg
Installation Lift Weight
70
Total Operational Weight
130
Pressures
CH Expansion Vessel
bar
Nominal Pre-charge
0.8
Safety Discharge
3
Max Operating
2.5
Min Operating
0.5
Recommend Operating
1-2
Max Capacity of
CH System
125 litres
Primary Water Content
of Boiler
3.2 litres
Pressures
bar
Max Operating
3.5
Min Operating
0.1
Min Operating Pressure
at 12 l/min
1.6
Flow Rates
l/min
DHW Flow Rate
@ 30
o
C Rise
14
DHW Flow Rate
@ 35
o
C Rise
11.5
Min Working
DHW Flow Rate
1
Max. Flow Rate
16 l/min.
Built In Bypass
l/h
Min Circulation Rate
200
(CH Primary Circuit)
e.g. TRVs all closed
Pump
Available Head
See graph below
Connections
copper tails
Gas Supply
-
22mm
Central Heating Flow
-
22mm
Central Heating Return
-
22mm
Cold Water Mains Inlet
-
15mm
DHW Flow
-
15mm
Pressure Relief Discharge -
15mm
Recommended System
Temperature Drop
11°C
20°F
Water Temperature
D.H.W. Flow Temp
(adjustable)
5° C to 65°C
max
(± 5°C)
Water Storage Volume
54 litres
Water Temperature
C.H. Flow Temp
(adjustable)
30° C to 82°C
max
(± 5°C)
Heat Input (gross)
Max
Min
C/H & DHW
kW
31.1
11.9
Btu/h
106,130
40,610
Heat Output
Max
Min
kW
28.0
10.4
Btu/h
95,555
35,492
Electrical Supply
230V~ 50Hz
Power Consumption
190W
External Fuse Rating
3A
Internal Fuse Rating
F2A
External Controls
230V switching
Electrical Protection
IP44 (IPx4D)
(Appliance must be connected to an
earthed supply)
Appliance Category
CAT II
2H 3+
Gas Rate
(Natural Gas)
Max
Min
(After 10 Mins) m
3
/h
3.29
1.26
ft
3
/h
116
44
Burner Pressure
(Natural Gas)
Room sealed panel fitted
mbar
10.6 ± 0.5
in wg
4.24 ± 0.2
Inlet Pressure
(Natural Gas)
mbar
20
in wg
8
Time To Raise Water Storage 50°C
13 minutes
DHW Circuit
Central Heating Primary Circuit
Reheat Time
70% of storage
10 minutes
Burner Injector
(Natural Gas)
18 x 1.18mm Diameter
Appliance Type
C
12
C
32
Nox Class
3
Unvented DHW Expansion Vessel
See Section 6.8 for information
This value is used in the UK Government’s
Standard Assessment Procedure (SAP) for
energy rating of dwellings. The test data from
which it has been calculated have been
certified by 0051.
SEDBUK Declaration For
Maxflow Combi WM
The seasonal efficiency (SEDBUK)
is 78.6 %
0
200
400
600
800
1
2
3
4
5
6
Metre wg
l/h
Pump - Available Head
0
1000
1200
LPG Gases / Propane and Butane
Burner Injector
18 x 0.69mm diameter
Burner Pressure
Propane mbar
in wg
Butane
mbar
in wg
Inlet Pressures
mbar
in wg
Butane
28
11.2
Max Rate
35.5
14.2
27.5
11.0
Min Rate
7.6
3.0
4.1
1.6
Propane
37
14.8
DHW Store Temp./Pressure Relief Valve
Maximum Pressure
7 bar
Maximum Temperature
90°C
DHW Inlet Pressure Relief Valve
Maximum Pressure
6 bar