8.0 Installation
20
8.4
Left Side and Vertical Flue (cont)
3. Slide the clip over one end of the air duct.
Engage the air duct over the flue duct.
4. Position the rubber seal equally over the joint
between the air duct and adaptor. Align the clip
with the seal and tighten the screws.
5. To fit the elbow take the rubber seal and
position it on the air duct. Pass the clip over the
air duct.
6. Engage the flue elbow on the air and flue ducts
and pull the seal to equally cover the joint.
7. Set the elbow to the required orientation. Align
the clip over the seal and tighten the screws
(Fig. 30).
8. Manoeuvre the boiler backwards into position,
and proceed to fit any extensions or bends as
required and the appropriate terminal.
8.5
Connecting the Pipework
(Fig. 31)
1. Connect the three brass extension pieces to
the CH flow, CH return and gas inlet adaptors on
the tap rail. Connect the fixed nuts to the
adaptors.
2. Connect two of the isolating cocks to the CH
flow and CH return extension pieces. Ensure that
the flow arrow on each tap is correctly oriented
and visible.
3. Loosely fit two of the 22mm copper elbows to
the CH flow and CH return taps and connect
them to the system pipework. Complete the
soldered joints.
4. Loosely fit the 15mm copper elbows to the
DHW flow and cold water inlet adaptors and
connect them to the system pipework. Complete
the soldered joints.
5. Connect the remaining isolating cock to the
gas supply extension piece and loosely fit the
remaining 22mm copper elbow to the gas supply
pipe. Complete the soldered joint.
6. Connect the copper extension piece to the
pressure relief adaptor on the tap rail. Ensure that
a 15mm fibre washer is between the joint.
7. Take the length of 15mm copper discharge
pipe from the kit and connect it to the pressure
relief valve. Fit the valve to the copper extension
and discharge pipe using fibre washers.
8. Disconnect all pipes and insert the correct
washer between the joints - fibre for water and
rubber for gas.
9. Tighten all pipe joints and ensure that the
square tap on each isolating cock will not prevent
correct fitting of the case top panel.
Fig. 28
Fig. 29
Rubber Seal
90° Elbow
Flue Adaptor
Clip
Rubber Seal
Flue Duct Clamp
Flue Duct
Air Duct
Flue Adaptor
Central Heating Flow
Extension Piece
Pressure Relief Valve
Central Heating Return
Domestic Hot Water Flow
Mains Water Inlet
Gas Inlet
Fig. 30
Fig. 31