6
© Baxi Heating UK Ltd 2006
Setting the Compact Heat Pump to work
Prior to use : -
1. Turn off the power supply at the local isolator.
2. Open the door, using a screwdriver.
3. Check that the ground pressure gauge reads at least 0.3
bar. If the pressure is lower than this, open the mains cold
water supply valve (fitted outside the case) fully until the
gauge reads at least 1.8 bar, at which point a "click" will be
heard. Close the mains cold water supply valve fully. If you
can’t find this valve, or when you open it the gauge reading
does not increase, call your installer and ask them about
the mains cold water supply valve on the slinky® ground
array circuit.
4. Check that the underfloor pressure gauge reads at least
0.3 bar. If the pressure is lower than this, find the mains
cold water supply valve, which is probably near your
underfloor heating manifold fully until the gauge reads at
least 1.8 bar, at which point a "click" will be heard. Close
the mains cold water supply valve fully. If you can’t find this
valve, or when you open it the gauge reading does not
increase, call your installer and ask them about the mains
cold water supply valve on the underfloor circuit.
5. Close and re-lock the door.
6. Turn on the power supply at the local isolator and
program the external timeclock / thermostat to use as
much off-peak electricity as possible.
Maintenance Instructions
No routine maintenance is required to Compact Heat
Pumps, and there are no user-serviceable components
inside. If further help is required then telephone our
helpline on 08700 603 261
Содержание Geoflo
Страница 5: ...5 Baxi Heating UK Ltd 2006 Technical Data ...
Страница 7: ...7 Baxi Heating UK Ltd 2006 Operating Instructions Trouble shooting P Pr rg g S Se el l ...
Страница 8: ...8 Baxi Heating UK Ltd 2006 Elevation of typical installation ...
Страница 9: ...9 Baxi Heating UK Ltd 2006 Recommended Installation Clearances All dimensions in millimetrs ...
Страница 10: ...10 Baxi Heating UK Ltd 2006 Hood Removal Clearances All dimensions in millimetrs ...
Страница 11: ...11 Baxi Heating UK Ltd 2006 ...
Страница 12: ...12 Baxi Heating UK Ltd 2006 ...
Страница 13: ...13 Baxi Heating UK Ltd 2006 Slinky Manifold Connections ...
Страница 14: ...14 Baxi Heating UK Ltd 2006 Pumbing Connections ...
Страница 15: ...15 Baxi Heating UK Ltd 2006 Output Pump Bleed Port ...
Страница 17: ...17 Baxi Heating UK Ltd 2006 Purging the Ground Arrays ...
Страница 19: ...19 Baxi Heating UK Ltd 2006 Control Box Layout ...
Страница 20: ...20 Baxi Heating UK Ltd 2006 Wiring Connections ...
Страница 23: ...Notes 23 Baxi Heating UK Ltd 2006 Notes ...