926.116.5 - en
INSTRUCTIONS FOR FITTERS
Consumption 15°C-1013 mbar
24 -1.24
24 F - 1.24 F
(
(
(
(
Rated power
2,78 m
3
/h
2,04 kg/h
2,73 m
3
/h
2,00 kg/h
Reduced power
1,12 m
3
/h
0,82 kg/h
1,12 m
3
/h
0,82 kg/h
p.c.i.
34,02 MJ/m
3
46,34 MJ/kg
34,02 MJ/m
3
46,34 MJ/kg
Table of burner injectors
24 -1.24
24 F - 1.24 F
gas type
G20
G31
G20
G31
diameter of nozzles (mm)
1,18
0,77
1,28
0,77
Burner pressure (mbar*)
REDUCED HEAT OUTPUT
2.5
5,4
2,0
5,7
Burner pressure (mbar*))
RATED HEAT OUTPUT
13,1
29,3
11,2
32,6
N° nozzles
13
Consumption 15°C-1013 mbar
1.14
1.14 F
(
(
(
(
Rated power
1,63 m
3
/h
1,20 kg/h
1,60 m
3
/h
1,17 kg/h
Reduced power
0,75 m
3
/h
0,55 kg/h
0,75 m
3
/h
0,55 kg/h
p.c.i.
34,02 MJ/m
3
46,34 MJ/kg
34,02 MJ/m
3
46,34 MJ/kg
Table 2
1.14
1.14 F
gas type
G20
G31
G20
G31
diameter of nozzles (mm)
1,18
0,77
1,18
0,77
Burner pressure (mbar*)
REDUCED HEAT OUTPUT
1.8
4,0
2,0
4,2
Burner pressure (mbar*)
RATED HEAT OUTPUT
8,0
17,7
8,5
19,1
N° nozzles
10
* 1 mbar = 10,197 mm H
2
O
Table 1