Dear Customer,

  

We are sure your new boiler will comply with all your requirements.

Purchasing one of the BAXI products satifies your expectations: good functioning, simplicity and ease of use. Do not dispose of 

this booklet without reading it: you can find here some very useful information, which will help you to run your boiler correctly and 

efficiently.

  

Do not leave any parts of the packaging (plastic bags, polystyrene, etc.) within children's reach as they are a potential source of 

danger.

  

 

CONTENT

 

SPECIAL ATTENTION BOXES ..........................................................................................................................................3

1. DESCRIPTION ...................................................................................................................................................................4

2. 

USER CONTROLS .............................................................................................................................................................4

3. 

OPERATING THE BOILER ................................................................................................................................................5

3.1  TEMPERATURE CONTROL ..............................................................................................................................................5

3.2  BOILER INFORMATION MENU  ........................................................................................................................................5

3.3  ERROR MESSAGES AND RESETTING THE BOILER .....................................................................................................6

3.4  OPERATING MODES.........................................................................................................................................................6

4. 

CENTRAL HEATING SYSTEM PRESSURE ......................................................................................................................7

5. 

SHUTTING OFF THE BOILER ...........................................................................................................................................7

6. 

FROST PROTECTION MODE ...........................................................................................................................................7

7. 

ROUTINE MAINTENANCE INSTRUCTIONS ....................................................................................................................8

8. 

CHECK LIST.......................................................................................................................................................................8

9. 

IMPORTANT NOTES .........................................................................................................................................................8

9.1  BOILER LOCATION ...........................................................................................................................................................8

9.2  FLUE TERMINAL ...............................................................................................................................................................8

9.3  POWER FAILURE ..............................................................................................................................................................8

9.4  ADDITIONAL BATHROOM FITTINGS ...............................................................................................................................8

9.5 CLEANING .........................................................................................................................................................................8

9.6 SERVICING ........................................................................................................................................................................8

9.7  GAS LEAK ..........................................................................................................................................................................8

9.8  ELECTRICAL SUPPLY .......................................................................................................................................................8

10.  MAINTENANCE SCHEDULES ..........................................................................................................................................9

Содержание DUO-TEC COMPACT 30 GA

Страница 1: ...GA LUNA DUO TEC 40 GA LUNA DUO TEC 1 33 GA en CONDENSING GAS FIRED WALL MOUNTED COMBINATION BOILER Instructions for the end user fr CHAUDI RE MURALE GAZ CONDENSATION DEUX SERVICES Notice d installatio...

Страница 2: ...lystyrene etc within children s reach as they are a potential source of danger CONTENT SPECIAL ATTENTION BOXES 3 1 DESCRIPTION 4 2 USER CONTROLS 4 3 OPERATING THE BOILER 5 3 1 TEMPERATURE CONTROL 5 3...

Страница 3: ...o not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a location external to the appliance Do not use this boiler if any part has been under water Immediate...

Страница 4: ...pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building I...

Страница 5: ...vent make up water FREEZE PROTECTION FLUIDS CAUTION NEVER use automotive or standard glycol antifreeze Even ethylene glycol made for hydronic systems Use only inhibited propylene glycol solutions whic...

Страница 6: ...ety trip control performed via a temperature sensor Press the RESET R button for at least 2 seconds If the this fault persists call an authorized SERVICE technician 128 Loss of flame Press the RESET R...

Страница 7: ...operation is 7 26 psi 0 50 bar If the pressure falls below 7 26 psi 0 50 bar this may indicate a leak on the central heating system The system must be re pressurised by your Service Engineer 5 SHUTTI...

Страница 8: ...the boiler or flue 9 2 FLUE TERMINAL The terminal on the outside wall must not be allowed to be obstructed If it is damaged in any way turn the boiler off and contact your Service Technician In cold...

Страница 9: ...contact your qualified service technician to inspect the unit and the vent combustion air system Check Pressure Gauge ensure the pressure reading on the pressure gauge does not exceed 25 5 psi 1 8 Ba...

Страница 10: ...sposal This discharge line must be installed by a qualified service technician or heating plumbing installer in accordance with the Boiler installation manual The discharge line must be terminated so...

Страница 11: ...fants ce sont des sources potentielles de danger SOMMAIRE ENCADR S POUR ATTIRER L ATTENTION 12 1 DESCRIPTION 13 3 MISE EN SERVICE DE LA CHAUDI RE 14 3 1 R GLAGE DE LA TEMP RATURE 14 3 2 MENU D INFORMA...

Страница 12: ...on lectrique la pompe Au lieu de cela couper l alimentation en gaz un emplacement externe l appareil Ne pas utiliser cette chaudi re si une ou plusieurs parties ont t sous l eau Contacter imm diatemen...

Страница 13: ...l ou de tout autre appareil QUE FAIRE EN CAS D ODEUR DE GAZ Ne tenter pas d allumer aucun appareil N actionner aucun interrupteur lectrique ne pas utiliser les t l phones situ s dans le b timent Appel...

Страница 14: ...UIDES DE PROTECTION CONTRE LE GEL ATTENTION Ne JAMAIS utiliser de glycol automobile de glycol antigel standard ou m me de l thyl ne glycol pr vu pour des syst mes hydroniques N utiliser que des soluti...

Страница 15: ...un capteur de temp rature Appuyer sur le bouton RESET R pendant au moins 2 secondes Si cette erreur persiste contacter un Service d assistance technique agr 128 Arr t de la flamme Appuyer sur le bouto...

Страница 16: ...r cela pourrait indiquer une fuite dans l installation de chauffage central Le syst me doit tre repressuris par un technicien d entretien 5 POUR TEINDRE LA CHAUDI RE Pour teindre la chaudi re d branch...

Страница 17: ...combustibles sur ou pr s de la chaudi re ou du conduit de fum es 9 2 TERMINAL DE FUM E Le terminal situ l ext rieur du mur ne doit jamais tre obstru S il est endommag de quelque fa on que ce soit tein...

Страница 18: ...entretien qualifi pour examiner l unit et le syst me d air comburant ventilation V rifier le manom tre s assurer que la valeur de pression indiqu e sur le manom tre ne d passe pas 25 5 psi 1 8 Bar EN...

Страница 19: ...nch la bouche de la soupape de d charge et orient vers un lieu d vacuation s r Cet conduit d vacuation doit tre install par un technicien d entretien qualifi ou par un installateur de plomberie chauff...

Страница 20: ...Baxi N A 2201 Dwyer Ave Utica NY 13501 1 844 4 BAXINA www baxiboilers com 7703471 01 1 03 18...