Baxi Combi 80e Скачать руководство пользователя страница 3

1.0 Warnings

3

1.1

Safe Installation

1. The appliance is suitable for installation only in
G.B. and I.E. and should be installed in
accordance with the rules in force. For Ireland
install in accordance with I.S.813 

“I

NSTALLATION

OF

G

AS

A

PPLIANCES

. The installation must be

carried out by a CORGI Registered Installer or
other registered competent person and be in
accordance with the relevant requirements of 

G

AS

S

AFETY

(Installation and Use) 

R

EGULATIONS

most

recent edition, the 

B

UILDING

R

EGULATIONS

issued

by the Department of the Environment, 

B

UILDING

S

TANDARDS

(Scotland) (Consolidation)

R

EGULATIONS

issued by the Scottish Development

Department and the 

L

OCAL

B

UILDING

R

EGULATIONS

.

Where no specific instructions are

given, reference should be made to the relevant

BRITISH STANDARD CODES OF PRACTICE
and INSTALLATION SPECIFICATIONS.

2. 

This appliance must be installed in

accordance with the manufacturer’s
instructions and the rules in force, and only
used in a suitably ventilated location.

3. 

Read the instructions before installing or

using this appliance.

4. Any purpose provided ventilation should be

checked periodically to ensure that it is free from

obstruction.

IMPORTANT

- The addition of anything that

may interfere with the normal operation of the
appliance without the express written
permission of Baxi UK Limited could invalidate
the appliance warranty and infringe the 

G

AS

S

AFETY

(Installation and Use) 

R

EGULATIONS

.

1.2

In case of gas leaks

1. If a gas leak is found or suspected, turn off the

gas supply at the meter immediately and at the

isolating valve on the boiler if possible. Contact

your Installer or Transco (under 'Gas' in the

phone directory).

1.3

Servicing your Appliance

1. For reasons of safety and economy your

appliance should be serviced annually. Servicing

must be performed by a competent person. Your

Installer or British Gas Service will be able to

advise you.

1.4

Electricity Supply

1. 

THIS APPLIANCE MUST BE EARTHED.

2. A standard 230V ~ 50Hz supply is required.

The appliance must be protected by a 3 amp

fuse.

Never Hang Flammable Items Over The

Appliance

STANDARD

B.S. 6891

B.S. 5440: Pt 1

B.S. 5440: Pt 2

B.S. 5546

B.S. 7074

B.S. 5449

B.S. 6798

SCOPE

Gas Installation.

Flues.

Air Supply.

Installation of hot water supplies
for domestic purposes.

Expansion vessels and ancillary
equipment for sealed water systems.

Forced circulation hot water systems.

Installation of gas fired hot water
boilers.

IN AN EMERGENCY

If a water or gas leak occurs or is suspected, the boiler can be

isolated at the inlet valves as follows;

1. Turn off the electrical supply and turn the selector switch on

the facia box to the OFF position.

2. Using a suitable open ended spanner or screwdriver turn the

square on the gas tap to the left to isolate the gas supply at the

boiler (Fig. 1).

3. The isolating valves are positioned under the boiler and can be

closed by turning their taps to the right towards the wall (Fig. 2).

4. Call your Service Engineer as soon as possible.

“Benchmark” Installation, Commissioning and Service
Record Log Book

Please ensure that your installer has completed the Installation

and Commissioning sections of the Log Book and hands the Log

Book over. The details of the Log Book will be required in the

event of any warranty work. Keep the Log Book in a safe place

and ensure that the relevant sections are completed at each

subsequent regular service visit.

Gas Tap

Heating Flow, Heating

Return and Mains

Water Inlet

Isolating Valves

Fig. 1

Fig. 2

All CORGI registered installers carry a CORGI identification card

and have a registration number. Both should be recorded in your

boiler Log Book. You can check your installer is registered by

telephoning 01256 372300 or writing to:-

1 Elmwood, 

Chineham Business Park,

Crockford Lane, 

Basingstoke,

RG24 8WG

Supplied by HeatingSpares247.com

Содержание Combi 80e

Страница 1: ...e 105e Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Please keep these instructions safe Should you move house please hand them over to the next occupier Supplied by HeatingS...

Страница 2: ...e we know that satisfied customers mean continued success We hope you get a satisfactory service from Baxi If not please let us know Natural Gas Baxi Combi 80e G C No 47 075 06 Baxi Combi 105e G C No...

Страница 3: ...d by a competent person Your Installer or British Gas Service will be able to advise you 1 4 Electricity Supply 1 THIS APPLIANCE MUST BE EARTHED 2 A standard 230V 50Hz supply is required The appliance...

Страница 4: ...1 have a dual function indicating the temperature of the central heating water when constantly illuminated If a fault develops the appropriate neon will begin to flash Refer to Sections 3 3 to 3 7 30...

Страница 5: ...mperature rises 5 Position ii In this position hot water will be provided when a tap or shower is turned on Fig 8 The hot water neon will illuminate Fig 5 6 The boiler will light automatically on dema...

Страница 6: ...ight or when incomplete lighting of the burner occurs Fig 11 2 Turn the selector switch fully anti clockwise against the spring pressure to the reset position R and release Fig 12 Set the selector to...

Страница 7: ...drops below the minimum requirement Fig 12 2 Check the pressure gauge as described in Section 3 9 If the pressure is in the normal range a pump fault is indicated Contact your Service Engineer to det...

Страница 8: ...during cold weather the boiler and whole system should be drained unless there is additional frost protection 3 Your installer will advise you about frost protection and draining the system IMPORTANT...

Страница 9: ...he compartment should be large enough to house the boiler and ancillary equipment only 5 IT SHOULD NOT BE USED AS A STORAGE CUPBOARD 4 2 Check List 1 If a fault develops or is suspected call your Serv...

Страница 10: ...can be found on the information label on the back of the hinged lower door Fig 22 5 3 Guarantee 1 Your Baxi Combi 80e or 105e is designed and produced to meet all the relevant Standards 2 Baxi UK Lim...

Страница 11: ...ting market Gas Central Heating Boilers Wall Floor and Fireside models Independent Gas Fires Renewal Firefronts Gas Wall Heaters Solid Fuel Fires If you require information on any of these products pl...

Страница 12: ...Baxi UK Limited Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN www baxi com After Sales Service 08706 096 096 Comp No 247939 Iss 3 6 01 921 653 1 Supplied by HeatingSpares247 com...