Keep hearth rugs and other soft furnishings etc. away from the front of the stove.

They could obstruct the free flow of hot air from the fan and damage both soft
furnishings and the stove.

Important Electrical Safety

The stove must 

not

be located in front of or under an electrical socket, the socket must

always be accessible in order to disconnect the stove from the electrical supply for
maintenance and cleaning.

Important! This stove must be earthed. 

The stove is supplied with a 3 pin 13 Amp fused re-wireable plug with 1mm² 3 core 

cable.

The wires in the cable are coloured in accordance with the following code: -

Live =Brown

Neutral = Blue

Earth = Green /Yellow

The electric supply must be safely routed from the stove to an electrical socket.

If the electric cable is damaged, to avoid a hazard it must be replaced by a Baxi Fires
Division authorised service agent, or similarly qualified person (See page 9). All
external wiring between the stove and the electrical supply shall comply with current
IEE regulations.

Page 5

INSTALLER AND OWNER GUIDE

© 

Baxi Heating U.K. Limited 2006.

Figure 1. Side clearances

Содержание Chester 0581901

Страница 1: ...r stove However if further information is required our Baxi Fires Division Technical Helpline will be pleased to help Telephone 08706 061 065 National call rates apply in the United Kingdom In the Republic of Ireland call 0044 8706 061 065 Important Please keep your guide in a safe place for future reference Baxi Heating U K Limited 2006 Model 0581901 Chester Log Effect Electric Stove ...

Страница 2: ...ing Baxi Fires Division All Baxi Fires Division stoves are designed to meet the most stringent quality performance and safety requirements to provide our customers with many years of trouble free service This guide aims to improve your understanding and appreciation of your new Baxi Fires Division stove by providing simple and informative instructions to enable you to install it and to ensure that...

Страница 3: ...vy then obtain assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the waist It is better to reposition your feet Avoid upper body top heavy bending Always bend from the knees rather than the waist Do not lean forward or sideways whilst handling the stove Always grip with the palm of the hand Do not use the tips of fingers for support Always ke...

Страница 4: ... Shower Rooms Swimming Pools etc Never use aerosols or steam cleaners on or around the stove Never route the electric cable under carpet etc Never install the stove close to curtains or combustible materials Never use the stove to dry clothes etc Never sit or stand on the stove POSITIONING THE STOVE Please read this guide thoroughly before positioning the stove Do I need any tools The stove has be...

Страница 5: ...rthed The stove is supplied with a 3 pin 13 Amp fused re wireable plug with 1mm 3 core cable The wires in the cable are coloured in accordance with the following code Live Brown Neutral Blue Earth Green Yellow The electric supply must be safely routed from the stove to an electrical socket If the electric cable is damaged to avoid a hazard it must be replaced by a Baxi Fires Division authorised se...

Страница 6: ... OPERATING THE STOVE Never cover the stove or obstruct the opening at the base of the stove this could cause overheating and consequent risk of fire The appliance can be controlled by the controls located underneath the controls cover Pull knob on front of stove Stove Controls The following switches are located under the controls cover Page 6 INSTALLER AND OWNER GUIDE Baxi Heating U K Limited 2006...

Страница 7: ...ll only work if the fan button has first been pressed Switches flame and fuel effect on and off Flame Dimmer Control Increases and decreases the brightness of the flicker effect Thermostat Control Adjust to maintain room temperature cycles between 900W and 1800W The thermostat only operates on the 1800W setting Both 900W indicator lights illuminated Page 7 INSTALLER AND OWNER GUIDE Baxi Heating U ...

Страница 8: ...he table lamp then it needs replacing as in the following sections The light bulbs fitted to this stove are 25Watt E14 230Volt Edison fitting candle style with a clear finish Due to the indeterminate life span and ease of replacement they are specifically excluded from the guarantee To replace the light bulb Open the door by pulling on the handle Remove the three screws on the front of the fuel ba...

Страница 9: ...tat on the stove is set above ambient room temperature Alternatively a cut out device is fitted to the stove to prevent damage due to over heating If it operates due to an obstruction in the airflow the stove must be turned off and allowed to cool for 15 minutes and the obstruction removed before restarting 4 I Have a problem that is different to those in the previous examples 1 3 Below is a list ...

Страница 10: ...ault problem or request Model Name and serial number This information can be found on a small label on the rear of the stove What should I do when I m ready to dispose of my stove The plug should be removed from the mains cable and the mains cable cut from the stove These should be disposed of with the stove Environmental Protection Waste electrical products should not be disposed of with househol...