10
© Baxi Heating UK Ltd 2009
Sedbuk Declaration For Bermuda
BBU 15 HE
The seasonal efficiency (SEDBUK) is 90.1%
This value is used in the UK Government’s
Standard Assessment Procedure (SAP) for energy
rating of dwellings. The test data from which it has
been calculated has been certified by 0087.
Appliance Category
CAT I
2H
Inlet Pressure
(Natural Gas - G20)
mbar
20
Injector
(Natural Gas - G20)
420 (4.2 mm)
Appliance Type
C
33
3.0 Technical Data
3.1
Bermuda HE CBBU 15 HE
NOx Class
5 (31mg/kWh)
Heat Input (Net)
Max
Min
kW
15.4
5.0
Heat Input (Gross)
Max
Min
kW
17.1
5.7
Heat Output (Non-Condensing)
Max
Min
kW
15.0
4.88
Heat Output (Condensing)
Max
Min
kW
15.7
5.25
Gas Rate
(Natural Gas - G20)
(After 10 mins)
Max
Min
m
3
/h
1.63
0.54
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Boiler Power Consumption
112W
Boiler Electrical Protection
IPX0
Boiler External Fuse Rating
3A
Connections
Gas Supply
-
15mm compression
Flow
-
22mm male copper
Return
-
22mm male copper
Weights
Packaged Boiler Carton
28 kg
Installation Lift Weight
27 kg
Flue Length
Max
Min
Metres
12.5
3.0
Dimensions
Casing Height
- 538mm
Casing Width
- 383mm
Casing Depth
- 306mm
Boiler Set Temperature
Max
Min
°C
75
25
Firefront
See the instructions supplied with the firefront for
all Technical Data
Содержание Bermuda BBU 15 HE