7604251 - v.01 - 08052013
6
Baxi Avanta Plus
3.3
Changing P3 setting: boiler regulation (domestic hot water and central heating mode)
0
= CH
off
/ DHW
off
1
= CH
on
/ DHW
on
(factory setting)
2
= CH
on
/ DHW
off
3
= CH
off
/ DHW
on
Change the boiler regulation as follows:
Press
[Enter]
-key until codes
pK
and
K1
are displayed alternately.
Press
[+]
-key 2x until codes
pK
and
K3
are displayed alternately.
Press
[Enter]
-key : central heating and domestic hot water mode
setting is displayed.
Press
[+]
or
[-]
key to change this mode, e.g. level
3
(= central heating
OFF and domestic hot water ON).
Press
[Enter]
-key to confirm this mode; codes
pK
and
K3
are
displayed alternately.
Press
[Reset]
-key to switch boiler to operating mode.
3.2
Changing P2 setting: domestic hot water temperature
Increase the domestic hot water temperature as follows:
Press
[Enter]
-key until codes
pK
and
K1
are displayed alternately.
Press
[+]
-key until codes
pK
and
K2
are displayed alternately.
Press
[Enter]
-key ; set value for domestic hot water temperature is
displayed: 55°C (= factory setting).
Press
[+]
or
[-]
key to change this value, for example to 65°C.
Press
[Enter]
-key to confirm value; codes
pK
and
K2
are displayed
alternately.
Press
[Reset]
-key to switch boiler to operating mode.
3 Changing boiler settings
3.1
Changing P1 setting: flow temperature of water in central heating system
Reduce the flow temperature as follows:
Press
[Enter]
-key until codes
pK
and
K1
are displayed alternately.
Press
[Enter]
-key again; set value for maximum flow temperature is
displayed: 75°C (factory setting).
Press
[+]
or
[-]
key to change this value, for example to 70°C.
Press
[Enter]
-key to confirm value; codes
pK
and
K1
are displayed
alternately.
Press
[Reset]
-key to switch boiler to operating mode.
R
1x
R
2x
R
Fig.2 Flow
temperature
Fig.3
Domestic hot water temperature
Fig.4 Boiler
regulation
LT.NL.W6H.000.070
LT.NL.W6H.000.071
LT.NL.W6H.000.072
3 Changing boiler settings