background image

standards, it is a heating appliance and certain parts of its surface will become hot.).

Do 

wait three minutes before attempting to relight if the fire is switched off or the 

flames are extinguished for any reason. (Your fire is fitted with a safety device that will
automatically shut off the gas supply to the fire if, for any reason, the flames 
go out).

Do 

get advice about the suitability of any wall covering near your fire. Soft wall 

coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected 
by heat. They may, therefore, scorch or become discoloured when close to a heating 
appliance. Please bear this in mind whenever you are considering redecorating.

Do 

provide a minimum side clearance as detailed in figure 1. Please bear this in mind if

ever you are considering altering the room.

Don’t

hang clothing, towels or any other fabrics over the front of the fire.

Don’t

add any extra ceramic fuel effect pieces above the number stated in the installer

and owner guide supplied with the ceramic fuel effect. This should have been placed
inside or attached to this guide by the installer. This could cause incomplete combustion
and consequent safety hazard.

Don’t 

put paper or any other material on the fire.

Don’t

place any combustible material (rugs, carpet, plastic tiles, etc.) on the hearth.

Don’t 

attempt to clean or service the fire until it has been switched off and allowed to

cool completely.

GAS CONSUMPTION

Model 759

Has a maximum natural gas input of 5.1kW (Gross)
Has a minimum natural gas input of 3.0kW

Page 6

OWNER GUIDE

Содержание 759

Страница 1: ...this appliance to be operated and maintained satisfactorily However if further information is required our Baxi Fires Division Technical Helpline will be pleased to help Telephone 08706 061 065 National call rates apply in the United Kingdom In the Republic of Ireland Telephone 0044 8706 061 065 This guide is intended to help you care for your Baxi Fires Division gas fire Please read thoroughly be...

Страница 2: ... made giving details of the proposed use to the following address The Company Secretary Baxi Heating UK Limited Pentagon House Sir Frank Whittle Road Derby DE21 4XA Warning Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages Baxi Fires Division Erdington Birmingham B24 9QP www firesandstoves co uk Because our p...

Страница 3: ...stem accepted by the British Standards Institute The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Baxi Fires Division is a CORGI registered company All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Gui...

Страница 4: ...t 9 Burner 10 CERAMIC FUEL EFFECT REFITTING 10 MAINTENANCE 10 USEFUL TELEPHONE NUMBERS 11 This gas fire is designed to meet the most stringent quality performance and safety requirements to provide you with many years trouble free service This guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to ensure that you benefit from ...

Страница 5: ...of wood or other combustible material where the shelf is not more than 150mm deep For a shelf deeper than 150mm add 12 5mm to the clearance for every 25mm of additional shelf depth See graph1 Do provide a suitable guard that complies with BS 8423 for the protection of young children the elderly and the infirm Such a guard is also recommended for the protection of pet animals Although this fire con...

Страница 6: ...ng Do provide a minimum side clearance as detailed in figure 1 Please bear this in mind if ever you are considering altering the room Don t hang clothing towels or any other fabrics over the front of the fire Don t add any extra ceramic fuel effect pieces above the number stated in the installer and owner guide supplied with the ceramic fuel effect This should have been placed inside or attached t...

Страница 7: ...e fire if the pilot flame goes out due to lack of oxygen or for any other reason If this device starts to repeatedly shut off the gas get expert advice This device incorporates a probe that senses that the heat from the pilot flame is correct Page 7 OWNER GUIDE PLEASE NOTE When operating your fire for the first time some vapours may be given off which may cause a slight odour and could possibly se...

Страница 8: ...to LOW While turning the burner flames should gradually become lower but remain alight Depress the control knob slightly to release from the LOW position and turn back clockwise to the Pilot ignition position The main burner should extinguish but the pilot should remain alight Depress the control knob slightly and turn back clockwise to turn OFF This will extinguish the pilot While cooling the cer...

Страница 9: ...are found anywhere in the fireplace have the chimney inspected before further use Metal parts and enamelled top Clean the metal or enamelled parts with a slightly damp cloth and then dry Do not use abrasive cleaners they could scratch the surface Ceramic fuel effect This product uses fuel effect pieces containing Refractory Ceramic Fibres RCF which are man made vitreous silicate fibres Excessive e...

Страница 10: ...The installer may have attached it to this guide or placed it inside It is important that the installer and owner guide for the ceramic fuel effect is followed correctly If replacing the ceramic fuel effect where a new guide is supplied follow the installer and owner guide supplied with the replacement fuel effect Keep the replacement installer and owner guide with this owner guide for future refe...

Страница 11: ... spare parts are available nationwide via the interpart stockist network For your local stockist consult Yellow pages under Central Heating When fitting replacement parts it is important that only approved parts are used for maximum safety USEFUL TELEPHONE NUMBERS General advice about gas and your gas fire BAXI FIRES DIVISION TECHNICAL HELPLINE 08706 061 065 To report faults or arrange for your fi...

Отзывы: