![Baxi 741FS Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/baxi/741fs/741fs_installers-manual_2711969017.webp)
There may however, be certain exceptional circumstances
where fitting the restrictor causes the fire to fail the
spillage test. In such cases the restrictor will have to be
removed. After removal conduct the spillage check again.
The restrictor is packed loose with the appliance and is
fixed with two screws (See figure 13).
7.
The upper corners of the hotbox flanges will have to
be cut away. The area to be cut away is shown in figure
14.
8.
There is a length of self adhesive foam seal supplied
with the fire. This will need to be fitted to the outer rear
edges of the side and top flanges of the hotbox. Be
careful not to stretch the seal when measuring. Remove
the protective backing from the foam seal and fit this to
the flanges (See figure 15). Ensure that there is no
gap between the foam seals where they meet at the
top flange (See figure 15)
9.
This appliance is supplied with a rear ceramic
support bracket. Fit this using two screws supplied
(See figure 16).
Page 17
INSTALLER GUIDE
Figure 14. Cutting the top corners of
the hotbox.
Figure 13
.
Flue restrictor