14
Warnings
before ignition
Please remember that appliance installation, first ignition, mainte
-
nance and repairs must be performed by qualified personnel.
Before turning on the appliance, proceed with suitable checks:
- Ensure the gas system seal is good (according to current regula
-
tions)
- Make sure mains data match those stated on the data plate
- Make sure the installation meets current local regulations
- Check the type of gas set for appliance operations on the serial
plate
- Make sure the flue meets current regulations
- Make sure the system pipes are free of residue, slag or dirt
- Check connections with the electrical mains, L-N polarity and
grounding connections
- Check the mains pressure as indicated in the next paragraph.
Checking the system pressure (minimum sup
-
ply pressure) (only for gas natural water heater)
- Unplug the water heater
- Removing the casing by unscrewing the fastening screws locat
-
ed on the bottom of the water heater and detaching the casing
from the upper part (Fig. 26)
- Remove the cover that closes the service inlet (located on the
shelf Fig. 12) and insert through the hole the silicon pressure
gauge tube
- Loosen by approximately two turns the screw of the pressure tap
upstream of the gas valve and connect the pressure gauge to it
- Carefully close the casing
- Turn the water temperature control knob to the maximum point
- Electrically connect the water heater
- Open a hot water valve to full capacity
Check the gas pressure referring to the values indicated in the data
table. If the pressure is higher than 15 mbar, calibrate the gas valve.
During measurement a tolerance of +/-0.5 mbar is permitted.
- Close the hot water tap
- Disconnect the pressure gauge and tighten the pressure tap up
-
stream of the gas valv
e.
Gas conversion
The gas conversion can be easily performed even while it is mounted.
The instructions for transforming and regulating the product to re
-
ceive various types of gas are below.
This operation must be performed by qualified personnel
according to law in force.
Disconnect the omni-polar switch outside the water heater and clo
-
se the gas and water valves to the appliance.
-
Remove the casing by referring to the specific paragraph
-
For LPG conversion: place the plate on the collector as shown
in fig. 13
-
Remove the clip (detail A fig. 14)
-
Disconnect and remove the gas pipe (detail B fig. 14)
-
Turn the screws showed in fig. 15 and lower the plate
-
Turn the collector fixing screws
- Extract the gas collector (fig. 16) and replace it
-
Reposition the components that had previously been removed
Fig. 12 - Check mains pressure
Fig. 13 - Placing of the plate
Fig. 14 - Disassembly burner
A
B
pressure tap upstream
of the valve
pressure tap downstream
of the valve
service
inlet