background image

Page 10

ZR-DC/WBX

Installation and Operating Instructions

CONNECTING THE TELEMETRY

You can use either coaxial or twisted pair telemetry with your ZR-DC/WBX. It switches automatically to the type of telemetry

it first receives after the power is applied.

Twisted-pair Telemetry

Connect Baxall 20 mA twisted pair telemetry to CON 3 on the main PCB. Either polarity is accepted.

Coaxial Telemetry

Baxall coaxial telemetry is connected as the video connections are made. Note that you can still connect the video through

the PCB if you use twisted-pair telemetry.

CONNECTING THE VIDEO

Connect all video using 75 ohm video coaxial cable terminated by BNC connectors. Connect the camera to VIDEO IN, and

the transmitter to VIDEO OUT.

Note

: In order for the auto pan and preset tour functions to operate correctly, the video from the camera must be routed

through the receiver PCB.

CONNECTING THE ALARM INPUTS

Your ZR-DC/WBX has 8 alarm inputs. The alarm inputs are split into two banks. Alarm inputs 1 to 4 are always configured

as normally open (N/O).  Alarm inputs 5 to 8 are configured as normally open unless the select terminal (SEL) is

connected to ground. In this case they become normally closed (N/C).

Note: When AL5 to AL8 are configured as normally closed, any unused alarm inputs must be connected to ground to

ensure correct operation.

CONNECTING THE ALARM OUTPUT RELAY

A normally open, volt-free relay contact is provided for alarm output purposes. This relay contact closes for approximately

one second for each new alarm condition. The relay is rated for a maximum of 3A at 240V AC.

Содержание ZR-DC/WBX

Страница 1: ...Please read this manual before installing your receiver ZR DC WBX DC Receiver Installation Instructions...

Страница 2: ...tion and Operating Instructions IMPORTANT The first few pages of these instructions contain important information on safety and product conformity Please read and ensure that you understand this infor...

Страница 3: ...eedback Potentiometers 8 Pan and Tilt head feedback potentiometers 9 Connecting the Telemetry 10 Connecting the Video 10 Connecting the Alarm Inputs 10 Connecting the Alarm Output Relay 10 Switch Sett...

Страница 4: ...for use in a general purpose CCTV installation and has no other function Do not exceed the voltage and temperature limits given in the specifications Only use your ZR DC WBX in a clean dry dust free...

Страница 5: ...R LAYOUT Shown below are the locations of the connectors switches LEDs fuses etc on the main and preset printed circuit boards Although shown separately for clarity the preset PCB is usually mounted a...

Страница 6: ...ds to be returned for whatever reason The packaging should contain The ZR DC WBX receiver These instructions Please inform your suppliers and carriers immediately if the product is damaged or any part...

Страница 7: ...devices operated by the system Typical Connections CONNECTING THE PAN TILT HEAD AND AUXILIARIES Referring to the instructions for your Pan Tilt head and auxiliaries connect them according to the sche...

Страница 8: ...the feedback pots For example it shows that as the lens is focused on a nearby object the focus feedback signal increases towards 5V The focus zoom and pan directions can easily be reversed using swit...

Страница 9: ...pply connection Connect the wires to CON 1 according to the following Pan potentiometer to terminal 5 Tilt potentiometer to terminal 4 Checking correct feedback potentiometer operation Set the DVM to...

Страница 10: ...O IN and the transmitter to VIDEO OUT Note In order for the auto pan and preset tour functions to operate correctly the video from the camera must be routed through the receiver PCB CONNECTING THE ALA...

Страница 11: ...UTPUT RELAYS The AUX A AUX B AUX C and AUX D relays can be programmed to respond to camera power wipe lamps wash or Aux 4 telemetry commands from the transmitter The contact configuration is shown bel...

Страница 12: ...o pan or Tour Auto pan is a software driven function and so does not need a specialised pan and tilt unit When you operate auto pan the Pan Tilt head pans for 60 seconds pauses 15 seconds pans in the...

Страница 13: ...ct Correct operation is indicated by a slow regular flash Other fault conditions are shown below If the video signal level is too low when it arrives at the transmitter then the telemetry can lose syn...

Страница 14: ...the position as preset n using the appropriate method for the transmitter or keyboard being used This is normally done by pressing the following keys in sequence F the function key n a number for the...

Страница 15: ...y Inputs Baxall Coaxial Telemetry or 20mA current loop twisted pair to the Baxall Telemetry specification Video Input 1V peak to peak composite video via 75 ohm BNC connector Video Output 1V peak to p...

Страница 16: ...e 5 10 00 Baxall Limited Stockport England Visit our Web site http www baxall com Baxall Limited reserve the right to make changes to the product and specification of the product without prior notice...

Отзывы: