Page 8
ZKX3-.. Keyboard
Installation and Operating Instructions
TERMINATING/BIASING THE BAXNET NETWORK
The keyboard has built in network termination and/or biasing. For most small to medium sized installations, it should not
be necessary to change the switches from their default settings. Only for large installations should your network require
biasing and/or terminating. Contact Baxall Security Limited for advice. The switches are shown below for your reference.
The default setting for switches 1, 2 and 3 is OFF. Switch 4 is not used.
BAXNET - UNIT IDs AND KEYBOARD PRIORITIES
The Unit ID is a number between 1 and 32. It is used to select a ZMX.. or ZTX6/.. for control from your keyboard and also
to decide the priority of one keyboard over another (lower numbers take precedence).
UNIT IDs - KEYBOARD PRIORITIES
The priority of keyboards over each other is determined by the value of the Unit ID. Keyboards with a lower value Unit ID
take precedence over keyboards with a higher Unit ID. A higher priority keyboard can take control of a ZMX.. or ZTX6/..
immediately and at any time from a lower priority keyboard. A lower priority keyboard must wait for 30 seconds from the
last command by the higher priority unit before it can take control. If another command from the higher priority keyboard
is sent in this time then it must wait another 30 seconds. The following control messages are displayed on on the ZKX
keyboard:
CONTROL LOST
Indicated when a higher priority keyboard on BaxNet has taken control or when the current keyboard
has timed out.
CONTROL UNIT #n Indicated when the current keyboard has control over all other keyboards on the BaxNet connection.
To re-activate control of a keyboard that has timed-out (CONTROL LOST), operate the pan or tilt keys.
UNIT IDs - LEGAL VALUES
IMPORTANT NOTE: Use the table to decide the Unit IDs. ZKX3-..s Unit IDs must be between 1 and 8
Setting the unit ID is included in the ZTX6/.. instructions, setting the unit ID on a ZMX.. is done in the COMMUNICATIONS,
RS485 menu and setting the unit ID on the keyboard is described below.
The following table gives the valid unit IDs for the listed products. Note that Unit ID 0 is reserved do not use it.
UNIT IDS - CHANGING THE UNIT ID ON YOUR KEYBOARD
Read these instructions thoroughly before attempting to change the Unit ID.
1. Disconnect the power from your keyboard
2. Reconnect the power
3. Within 5 seconds of reconnecting the power, press the two keys shown below simultaneously.
AND
Unit
Possible Unit IDs
ZKX3-..
1 to 8
ZMX..
9 to 32
ZTX6/..
9 to 32
4
OFF
UP
ON
3 2 1
*Default setting
Network setting
Switch 1
Switch 2
Biased
ON
ON
Not Biased*
OFF*
OFF*
Network setting
Switch 3
Terminated
ON
Not Terminated*
OFF*
*Default setting