Page 6
X Series DSP Cameras
Installation Instructions
FUNCTION SWITCHES
AGC (Automatic Gain Control)
The Automatic Gain Control feature can improve picture quality when the level of illumination is
low. Select
ON
or
OFF
using dip switch SW1-1. For most applications, the AGC feature should
be
ON
and is therefore the default setting.
LL-PH (Line Lock, Phase Adjust)
The Line Lock, Phase Adjust feature is selected by dip switch SW1-2. Choose
FIX
(fixed) or
ADJ
(adjustable). Both settings are line-locked however, the
ADJ
setting allows ±120
O
phase
adjustment via the potentiometer located on the rear of the camera. The
ADJ
mode should be
used when cameras are connected to different mains supply phases (R, Y, B). Default setting
is
FIX
.
SYNC (Synchronisation)
The Synchronisation feature is selected using dip switch SW1-3. Choose
L/L
(Line-Lock) or
INT
(internal).
L/L
locks the frame rate to the mains so that cameras are triggered at the same
point on the mains supply AC cycle.
INT
locks the frame rate to the internal oscillator of the
camera. The default setting is
L/L
.
Shutter speed switches
Shutter speeds are selected with dip switches SW2-1, SW2-2, SW2-3 and SW2-4. Dip switch
SW2-1 must be down to enable manual shutter speed selection. For EI, BLC and Flickerless
functions, switch SW2-1 must be up.
SW1
SW2
SW3
1
1
1
2
2
2
3
3
3
4
4
4
5
6
AGC OFF
AGC ON
1
SW1
SW2
SW3
1
1
1
2
2
2
3
3
3
4
4
4
5
6
FIX
ADJ
2
SW1
SW2
SW3
1
1
1
2
2
2
3
3
3
4
4
4
5
6
INT
L/L
3
SW1
SW2
SW3
1
1
1
2
2
2
3
3
3
4
4
4
5
6
1/4,000
1/1,000
1/250
1/50
1
1/10,000
2 3 4
1
1/2,000
2 3 4
1
1/500
2 3 4
1
1/100
2 3 4
All manuals and user guides at all-guides.com
all-guides.com