Parameter
V-Controller (BUS 6 VC)
33
Baumüller Nürnberg Electronic GmbH & Co. KG
5.03047.01
7.2
Power Unit
Parameter overview
Parameter description
P115
PU
state
This parameter displays the state of the power unit.
Parameter
Name
Range
min. ... max.
Unit
Display
only
P115
PU
state
0000 ... FFFF
!
P090
PU
mode
0000 ... 0007
P117
PU
type
0.1 ... 65535
!
P114
PU
I nominal
0.1 ... 2500,0
A
!
P113
PU
I max
0.1 ... 2500,0
A
!
P119
PU
overload time
0.00 ... 600,00
s
!
P116
PU
I limit
The range depends on the PU.
Permitted range:
≤
PU
I limit
≤
PU I max
A
P118
PU
temperature
-80 ... 130
°C
!
Bit no.
Meaning
0 ... 2
0 : STOP 1 : RUN
3
1 : Error in function module, error code see M error code (P124)
4
1 : Power unit reset is active
5
1 : Pulses are enabled, power unit is active
6
1 : Power unit temperature > 80 °C
7
1 : Power unit ready for use
8
1 : PU monitoring is active, current reduction to 100% I
nom
power unit
9
1: Short circuit temperature sensor
10 ... 15
reserved
PU Inom
4
------------------------
Содержание BUS 6 VC
Страница 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Страница 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Страница 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 16: ...Transportation Unpacking 14 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Страница 109: ......