Ready-for-use (= BB)
Manual Single Power Unit BUM64S/A/F
Document no.: 5.01056.03
Baumüller Nürnberg Electronic GmbH & Co. KG
66
8.3
8.2.1
Monitoring functions of feed module
The messages generated by the "infeed module monitoring functions" are transmitted
outside by using relay contacts. Simultaneously the messages are transmitted to the con-
troller and processed there.
figure 23: Position of relay contacts
Further information about messages and their respective relay contacts you will find un-
der
8.2.2
Monitoring functions of motor-side power module
The messages generated by the "motor-side power module monitoring functions" are ex-
clusively transmitted to the controller and processed there. Further information you will
find under
8.3
Ready-for-use (= BB)
The “ready-for-use“ message is the most important message. When a monitoring function
generates a message, that erases the "ready-for-use" message, the drive will be stopped.
There is not only one single message “ready-for-use“. If, for example there is a V-control-
ler in your BUM 64S/A/F, each drive will have four different "ready-for-use" messages.
m
"ready-for-use feed module" (in BUM 64S/A/F existent and visible)
= "ready-for-use internal" (digital output X99A - 5)
= "ready-for-use external" (relay contacts X99AB - 1,2)
m
"ready-for-use power module" (in BUM 64S/A/F existent and
not
visible)
m
"ready-for-use controller" (existent in controller)
m
"ready-for-use group" (existent in controller)
The "ready-for-use group" message depends on three other ready-for-use messages.
Only if the messages "ready-for-use feed module" and "ready-for-use power module" and