Operation
Manual Single Power Unit BUM64S/A/F
Document no.: 5.01056.03
69
8
8.4
Monitoring functions
The following table lists all monitoring functions of the power unit. A description of each
monitoring function you will find on the following pages
1)
The V-controller display this accumulative error message when there is an error in the feed module. Which
error has occurred is shown by the respective LED on the unit’s front side.
2)
Trigger the reset input (+24V and M24V applied at X99AB, optocoupler input).
or
cut off +24V-supply voltage.
That way
all
messages of the feed unit will be erased!
If you react on the WARNING you will have the possibility, to bring the drive into a defined operational status,
before the power module erases the "ready-for-use feed module" message and switches to powerless state.
3)
Not possible by use of the reset input! For safety reasons you must wait, until the DC link is discharged (U
ZK
< 20 V). After that you can switch off the +24V-power supply.
That way
all
messages of the feed unit will be erased!
4)
The message must be erased by a reset of the controller.
Display and erasure of the message is described in the controllers documentation
5)
A message only appears, when the safety relay is switched off. The safety relay is switched off, when the
+24V-supply voltage is not present at the relay.
Before you are enabled to erase the message by a reset of the controller, you must restore the +24V-supply
voltage at the relay.
monitoring function
LED
relay
V-controller
reset
feed
module
phase failure
WARNING
PHASE ERR.
-
X99AB; 3,4
-
F 0110
1)
-
24 V
DC
2)
mains network failure
WARNING
POWER ERR.
-
X99AB; 3,4
-
F 0110
1)
-
24 V
DC
2)
short-circuit ballast output
BRAKE OVERL.
-
F 0110
1)
U
ZK
3)
motor-side
power
module
overcurrent (motor)
e.g. short-circuit
-
-
F 0202
contr.
4)
earth current (motor)
e.g. short to earth
-
-
F 0203
contr.
4)
DC link overvoltage
-
-
F 0201
contr.
4)
heatsink overtemperature
-
-
F 0205
contr.
4)
internal auxiliary voltage
-
-
F 0204
contr.
4)
safety relay
-
X 68; 1,2
5)
F 0206
contr.
4) 5)
NOTE
Reset
: If the message cannot be reset, it is very likely, that the reason for the error is still there.
Содержание BUM64A
Страница 1: ...E 5 01056 03 Manual Single Power Unit BUM64S A F ...
Страница 76: ...Manual Single Power Unit BUM64S A F Document no 5 01056 03 Baumüller Nürnberg Electronic GmbH Co KG 76 of 118 ...
Страница 86: ...Manual Single Power Unit BUM64S A F Document no 5 01056 03 Baumüller Nürnberg Electronic GmbH Co KG 86 of 118 ...
Страница 119: ......