Commissioning
Mono Power Unit BUM 62 T
61
Baumüller Nürnberg GmbH
5.99009.03
7.3.4 Messages via relay contacts
Plug-in terminal
Description
X99AB
"Supply part ready"
Contact
open
:
The message ”Supply part ready” is not activated.
Contact
closed
:
The message ”Supply part ready” is activated.
Further information on the message ”Supply part ready” can be obtained from ”Supply part ready”
page 54
.
X99AB
Early warning - interference
Contact
closed
:
The WARNING message is not activated.
Contact
open
:
The WARNING message is activated.
”Phase failure monitoring function” page 56 and ”Mains failure monitoring function” page 56 will
inform you in which cases the message is activated.
X68
For an immediate production restart, it is necessary to stop a drive electronically to achieve
the following:
y
no contactors in the motor cables are necessary
y
DC link voltage does not have to be switched off.
This requirement is met by using a safety relay.
Feedback of safety relay (safety relay is available as an option)
Contact
closed
:
No +24 V supply for the safety relay. The power stage or the inverter is inhibited.
Contact
open
:
+24 V supply for the safety relay is applied. The power stage or the inverter can be triggered by the
controller.
If the +24V supply for the safety relay is no longer applied while the drive is running, the drive no
longer supplies a torque (i.e. there is no supply from the BUM 62 T).
To restart the drive, proceed as follows:
y
Switch on +24 V supply for the safety relay
y
Clear the existing message by a controller reset
Содержание BUM 62 T
Страница 1: ...E 5 99009 03 Manual BUM 62 T Mono Power Unit ...
Страница 6: ...6 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Страница 10: ...Safety notes 10 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Страница 16: ...Technical data 16 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH 3 3 Block diagram ...
Страница 18: ...Transportation Unpacking 18 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Страница 21: ...Assembly Mono Power Unit BUM 62 T 21 Baumüller Nürnberg GmbH 5 99009 03 Installation Dismantling ...
Страница 22: ...Assembly 22 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Страница 39: ...Installation Mono Power Unit BUM 62 T 39 Baumüller Nürnberg GmbH 5 99009 03 6 5 Connection diagram ...
Страница 48: ...Installation 48 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Страница 62: ...Commissioning 62 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Страница 66: ...Maintenance 66 Mono Power Unit BUM 62 T 5 99009 03 Baumüller Nürnberg GmbH ...
Страница 73: ......