Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
88
3.4
3.4.2.8 Description of the Parameters
19.1
Number of motors
Number of axes. The value of the parameter is automatically set by the controller during
the boot process, using the device identifier (
Hardware name).
138.10
External limiting max
field current amplitude
FLOAT
0
10000
10000
A
1:1
X
138.11
Iq set value before notch
filter
FLOAT
-10000
10000
0
A
1:1
X
138.12
Center frequency Iq set
value notch filter
FLOAT
0
8000
0
Hz
1:1
X
138.13
Bandwidth Iq set value
notch filter
FLOAT
0
4000
50
Hz
1:1
X
138.14
Iq limit bipolar cyclic
UINT
0
16384
16384
%
4000
hex
:100%
X
138.15
Iq limit bipolar
FLOAT
0
100
100
%
1:1
X
138.16
Speed threshold for
breakdown torque limit
FLOAT
0
1e9
0
U/min
1:1
X
138.17
Factor for breakdown
torque
FLOAT
0
1.41
0.9
1:1
X
138.18
Iq limit breakdown
torque
FLOAT
0
1e9
0
A
1:1
X
138.20
Max. torque actual value UDINT
0
0xFFFFFFFF 0
Nm
1000:1
X
138.21
Torque display
DINT
0x80000000
0x7FFFFFFF
0
Nm
1000:1
X
138.22
Torque limit symmetric
UDINT
0
2147483647
2147483647
Nm
1000:1
X
X
138.24
Indication threshold
torque
UDINT
0
2147483647
2147483647
Nm
1000:1
X
X
138.25
Status current limitation UDINT
0
0xFFFFFFFF 0
1:1
X
138.26
Limitation max current of
IPMSM
FLOAT
0
1e9
0
A
1:1
X
138.28
Hysteresis for Iq limit
flag
FLOAT
0
50
5
%
1:1
X
138.29
Time constant torque
display
FLOAT
0
1000
3
ms
1:1
X
138.30
Max. torque current
actual value
FLOAT
0
10000
0
A
1:1
X
138.32
Peak current derating
FLOAT
0
10000
0
A
1:1
X
138.34
Torque base value
FLOAT
0.001
1.0e6
0.001
Nm
1:1
X
146.1
Asynchronous Motor
Mode
UINT
0
0xFFFF
0
1:1
X
146.13
Flux set value
FLOAT
-1e9
1e9
1
%
1:100
X
146.14
Actual flux
FLOAT
-1e9
1e9
0
%
1:100
X
146.16
Slip preset value
DINT
0x80000000
0x7FFFFFFF
0
Inc/
Tab
1:1
X
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......