Diagnosis
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
688
3.10
101.2
Command
If it is not possible to start the recording, the available memory is insufficient.
If the ring buffer is in Status 4 (Waiting for Read Out), the recording can also be restarted
without read-out.
101.3
Channel 0 source parameter Id
Specification of the parameter ID of the signal to be recorded.
Only parameters with scalar data types can be recorded (no array elements, no structure
elements).
Only real-time capable parameters can be recorded for which the access function does
not exceed a specific minimum time. The controller checks the ID and reports a corre-
sponding error message to the operating system if the parameters are not real-time ca-
pable.
101.4
Channel 1 source parameter Id
See
101.5
Channel 2 source parameter Id
See
Value
Meaning
0
Recording Stop
1
Recording Start
2
Activate trigger
3
Reset, deletes error, redistributes memory
NOTE!
Before a trigger event bit is accepted, the trigger ID and trigger axis mask must be
entered! In addition, the trigger ID for all axis indicated in the trigger axis mask must
be entered in the channels for the corresponding axis.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......