3
145.5
Speed limit master axis
Display of maximum editable speed (= Position Change) at the transmission input (mas-
ter axis) to prevent overrun at the transmission output (slave axis). The value is calculated
based on the current transmission factors.
If the set value of the master axis exceeds this value, a error will be issued and the sub-
sequent drive will be blocked. Monitoring may occur with an incorrect setting of the trans-
mission factor or a faulty set value of the master axis. Normally, these high speeds cannot
occur.
The maximum possible value (= 2147483647 Inc/T
ab
) is displayed at the transmission in-
put for |
Rot. slave axis| <
Rot. master axis.
The sampling time T
ab
in the unit of Parameter
corresponds with the effective
position controller cycle (refer to
RT0 cycle time).
Example:
Position controller cycle = 250 µs
Inc/T
ab
= Inc/
250µs
revolution of the slave axis = -55555
revolution of the master axis = 1000
= (2
31
-1) * Rot. master axis / |Rot. slave axis|
= 2147483647 * 1000 / 55555
= 38655092 Inc/
250µs
The result converted to a rotative speed:
Speed limit = 38655092 * 4 Inc/ms = 1546220368 Inc/ms
= 1546220368 * 60000 / 2
32
rpm
2160 rpm
145.6
Synchronization velocity window
This parameter is used to set the monitoring window for the speed synchronicity. The
Synchronization Velocity window is symmetrically arranged around the speed set value
of the master axis.
If the speed actual value of the slave drive is outside of this window under consideration
of the electric transmission, bit 9 "Slave axis outside of synchronization velocity window"
will be set in the
status. If the speed actual value of the slave axis enters the
monitoring window again, bit 9 will be deleted again.
Monitoring is not activated until speed synchronization is completed (
Status
bit 8 = 0).
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......