Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
427
3
Remark:
Bit 12:
1: Actual speed is equal to speed set value (= set value reached)
The following conditions must be satisfied for "Set Value Reached" to be set:
e2 speed error
Max. pos. speed difference
and
e2 speed error
Max. neg. speed difference
and (optional)
e2 speed error
Speed set value total *
Velocity window percentage
18.21
w2 speed set value total
Display of the total currently effective speed set value in degrees/s.
With speed control:
w2 Speed set value total =
Speed set value output Set
Speed set value add
With absolute position control:
w2 Speed set value total = (
Speed set value output SetValMgr *
w2-feedforward factor)
Speed set value add +
e1 position controller error *
Kv position controller)
12
1: Actual speed is equal to speed set value (= set value reached)
13
1: Torque current set value is limited
14
1: Torque reduction according to braking procedure ended
15
1: Torque reduction according to braking procedure active
16
1: Torque reduction by means of DC link controller
17
Reserved
18
1: Torque reduction by mains failure
19
1: Integral term Speed Controller is limited
20
1: Torque current limiting after the notch filter
21
1: Torque current limiting after the polynomial filter
22
1: Holding torque buildup by brake manager active
25 … 23
Reserved
26
1: Torque current set value is limited (hysteresis)
Compared to bit 13 this bit is reset not before the torque current set value
is fallen below the effective limit by the adjustable hysteresis
31 … 27
Reserved
Bit
Meaning
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......