Performing the commissioning (using Axis 1 as an example)
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
34
2.6
14
The following window appears.
Figure 17:
ProDrive: Selecting the motor
15
In this window, enter:
m
the motor type „synchronous“
m
the nominal voltage for the motor DC link: "540 V"
m
the nominal speed: "6000 rpm"
m
select the motor type: "DS 56-S"
m
the maximum speed is automatically taken from the value for the nominal speed
16
Click on the
OK
button.
At this point all the data will be transferred from the motor database to the corresponding
parameters and display fields.
17
Check all the values for the motor using the motor data sheets (This is only for check-
ing purposes if you are using the Baumüller motor database. If you are employing mo-
tors from third-party manufacturers, you must do this in any case).
NOTE
The values for nominal speed and maximum speed are the same for synchronous
motors and are thus adopted for the maximum speed when selecting the nominal
speed.
With asynchronous motors, the two values must be selected separately. Software for
asynchronous motors: in preparation.
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......