3.4
128.1
Motor temperature status
Status of the motor temperature measurement and monitoring:
128.2
Temperature acquisition system
This parameter is used to switch the motor temperature detection and monitoring on and
off, and also the determine the connection to the device.
128.3
Motor temperature
Display of the measured motor temperature in °C
Is important if the motor temperature monitoring is switched on (value
bits 0 to
7
≠
0 and 1 and 3), only.
Bit
Meaning
0
0: Motor temperature monitoring switched off
1: Motor temperature monitoring switched on
3 ... 1
Reserved
4
1: Warning threshold 1 exceeded
5
1: Warning threshold 2 exceeded
6
1: Switch-off temperature reached
7
1: Overtemperature detected by temperature switch
8
1: Short circuit detected on temperature encoder
9
1: Temperature encoder is not connected
15 ... 10
Reserved
Bit
Meaning
7 ... 0
Selection of the connection for the motor temperature encoder:
0:
No encoder, or motor temperature monitoring off
1:
Connection to encoder input, standard connection
2:
Connection to encoder input, non-standard connection
3:
Connection to power unit
4 … 255 reserved
15 ... 8
Reserved
Содержание b maXX BM5800
Страница 10: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 10 of 814 Contents ...
Страница 724: ...Monitoring Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 724 of 814 3 11 ...
Страница 756: ...Error descriptions Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 756 of 814 4 5 ...
Страница 800: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 800 of 814 ...
Страница 808: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 808 of 814 ...
Страница 814: ...Parameter manual b maXX BM5800 Document No 5 16029 03 Baumüller Nürnberg GmbH 814 of 814 Notes ...
Страница 815: ......