The digital in- and outputs are opto-isolated. The supply voltage must externally be provided (24V). In the
device the ground of the digital inputs is
not
connected to earth of the supply voltage and must be separately
connected.
The following figures show the principle schematic diagram.
GNDIO
SH
IF
DI4
DI3
DI2
DI1
X26
Figure 6.36: Digital inputs
DO1
DO2
DO3
DO4
I_O4
OUT4
OUT3
OUT2
I_O3
I_O2
I_O1
OUT1
VN340SP
BB
GNDIO
BBS
BBO
BBW
RELS
RELO
RELW
X26
DOUT1
DOUT2
DOUT3
24VIO
Figure 6.37: Digital outputs
Instrution
Manual
b
maXX®
BM3400
97
Do
ument
No.:
5.07013.03
from
206
Содержание b maXX BM3400 Series
Страница 1: ...E 5 07013 03 Instruction Manual b maXX BM3400 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...T 0 10 Instru tion Manual b maXX BM3400 from 206 Do ument No 5 07013 03 Baumueller Kamenz GmbH ...
Страница 144: ...T 10 Repair 144 Instru tion Manual b maXX BM3400 from 206 Do ument No 5 07013 03 Baumueller Kamenz GmbH ...
Страница 165: ...De laration of Conformity C 5 T Instru tion Manual b maXX BM3400 165 Do ument No 5 07013 03 from 206 ...
Страница 191: ...E Appendix E List of gures Instru tion Manual b maXX BM3400 191 Do ument No 5 07013 03 from 206 ...
Страница 195: ...F Appendix F Index Instru tion Manual b maXX BM3400 195 Do ument No 5 07013 03 from 206 ...
Страница 196: ...T F Appendix F Index 196 Instru tion Manual b maXX BM3400 from 206 Do ument No 5 07013 03 Baumueller Kamenz GmbH ...
Страница 202: ...T F Index 202 Instru tion Manual b maXX BM3400 from 206 Do ument No 5 07013 03 Baumueller Kamenz GmbH ...
Страница 204: ......
Страница 205: ... ...