4.7.7.3 Adaption EMF feed forward
As shown in
the EMF feed forward in the torque current controller is depen-
dent of the flux set value and of the motor voltage constant.
Figure 173:
EMF feed forward
with: Motor
Ke
factor
The ASM is dependent of the magnetic flux of the saturation influence (refer to
4
Ks adaption cyclic
0: inactive
1: active
5
Kd is set to 0 (direct speed controller adaption)
7 ... 6
Adaption according to (direct speed controller adaption):
00: Actual value
01: Set value
10: Speed feedforward
11: Free usable parameter
15 … 8
Reserved
Bit no.
Meaning
5000_0346_rev01.cdr
Motor Ke
Flux act. value 145.13
100
Back-EMF
feed forward
47.26
Speed
act. value
18.22