Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
515
4
152.3
Input
Parameter number of the input of the two-level controller. With value 0 no comparison to
absolute thresholds operates.
152.4
Relative compare value
Parameter number of the relative compare value. With value 0 no comparison to relative
thresholds operates.
152.5
Lower threshold absolute
If the data type of the parameter selected with
is FLOAT, then this parameter
forces the lower absolute switching threshold.
The absolute two-level controller switches on, if the following is valid:
Parameter number actual value
lower absolute switch threshold
152.6
Upper threshold absolute
If the data type of the parameter selected with
is FLOAT, then this parameter
forces the upper absolute switching threshold.
The absolute two-level controller switches off, if the following is valid:
Parameter number actual value
upper absolute switch threshold
152.7
Lower threshold relative
If the data type of the parameter selected with
is FLOAT, then this parameter
forces the lower relative switching threshold.
The relative two-level controller switches on, if the following is valid:
Parameter number actual value
parameter number relative compare value +
lower relative switch threshold
2
Status indication of the relative two-level controller
0: Output relative two-level controller inactive
1: Output relative two-level controller active
15 … 3
Reserved
Bit
Meaning