Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
487
4
47.44
Ud after PWM
d-voltage after calculating the modulation levels.
47.45
Rho-RT0
Display of Phi Set Value which the controller receives.
47.46
Delta-Rho in Inc/ I-controller-clock
Display of delta_Phi Set Value which the controller receives.
47.47
Motor Rho
Displays the current motor angle for field-oriented control.
Standardization: 0xFFFF for 360 degrees.
47.49
Output frequency filtered
Frequency (actual value) of the output voltage smoothed with 4 ms.
47.50
Dead time compensation
Dead time compensation factor: 100% means that exactly the determined voltages have
been pilot controlled. The standard value is 0%, i.e., no compensation.
Compensation can be carried out using measured values or with default values (if dead
time measurement wasn't executed). See dead time correction table
47.51
Current controller mode
Switches the current prediction for the current controller on/off.