Controllers
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
454
4.7
The parameter must not be confused with the Actual Operating Mode parameter
18.7
Adaptation time parameter
To prevent excitation, any change to the Gain parameters Kv (
) or Kp (
) when the position or speed controller is switched on is made in stages. I.e., during any
change to the controller parameter Kv and Kp, the newly entered value only becomes fully
effective after the time registered here [ms].
The step time is fixed at 50ms for this.
Example:
= 1950 ms
A change of Kp or Kv from the old value to the new one is performed in 39 steps
(1950ms/50ms).
18.9
Controller options
Value
Meaning
Remark
Examples of Drive Operating Mode
(
10
Measure
Notch position search (-1)
Autotuning (-7)
11
Reserved
12
Absolute position con-
trol
Controller structure,
Target position setting (1)
Reference run (6)
13
Speed control
Controller structure,
Speed control (-3)
Speed setting 1 (2)
14
Torque control
Controller structure,
Current Control (-2)
15
Reserved
16
Synchronous operation
Controller structure,
Synchronous Operation (-5)
Bit
Meaning
0
Reserved
1
Calculation of the acceleration feedforward for position controlled operat-
ing modes
0: from the set value of the speed feedforward
1: from the total speed set value
A change of bit 1 is only effective at drive block and again enabling.
2
1: External cyclic acceleration feedforward via
; effective only in
operating mode Position control (-4)
3
1: External cyclic speed feedforward via
; effective only in operat-
ing mode Position control (-4)