Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
437
4
4.6.6
Motor potentiometer
Changes of the speed set value can be forced by the motor potentiometer depending on
two control bits (Motor potent and Motor potentiometer-). The motor potentiom-
eter writes directly on the ramp function parameter
The motor potentiometer is activated via the control parameter
Mode.
The motor potentiometer parameter
Increment indicates the amount of the in-
crease/decrease of the motor potentiometer output
.
Parameter
bit 4 sets whether the motor potentiometer function operates edge
sensitive or level sensitive:
m
edge sensitive
bit 1 Motor potent or
bit 2 Motor
potentiometer-,
Increment is added or subtracted once.
m
level sensitive
bit 1 Motor potent or
bit 2 Motor
potentiometer-,
Increment is added or subtracted every 32 ms.
The output of the Motor potentiometer is limited by an upper and a lower limit.
The output of the Motor potentiometer is set to 0 or is synchronized with the ramp function
generator parameter
Input 16 bit depending on parameterization of
Mode bit 3 at activation of the Motor potentiometer.
The output of the motor potentiometer
is checked for limits and if necessary ad-
justed in case of Motor potenti/- is activated. If the upper limit is changed so that
the output of the Motor potentiometer is greater than this limit, the output is adjusted
downwards with an activated Motor potent function. The modification occurs di-
rectly without transient.
4.6.6.1 Parameter Overview
Function block:
FbMotorpotentiometer[168]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read
on
ly
St
o
ra
g
e
D
S
Su
pp
or
t
Cyclic W
rite
168.1
Status
WORD
0
0xFFFF
0
1:1
X
168.2
Mode
WORD
0
0xFFFF
0
1:1
X
X
168.3
Output
INT
-16384
16384
0
%
16384:
100
X
168.4
Upper Limit
INT
-16384
16384
16384
%
16384:
100
X
168.5
Lower Limit
INT
-16384
16384
-16384
%
16384:
100
X
168.6
Increment
INT
0
2000
100
%
100:1
X
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......