Set Value Generators
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
430
4.6
Relative mode
m
Relative mode
If the relative mode is active, the value of the reference parameter is frozen, after the
cam generator is started. This frozen value is added to the output of the cam generator
output. This has no effects, if the reference parameter changes during the cam pro-
cessing at an active cam generator. At the activation of the cam generator, the refer-
ence parameter value remains, until the cam generator freezes the new actual value
of the reference parameter at the next transmission from the state "active" into "run".
m
No relative mode
If the relative mode is not active, the actual parameter value, which is selected in
, is added to the output of the cam generator. The starting of the cam gener-
ator does not freeze the parameter value.
Automatic offset
If the setting
AutoOffset
is made in parameter
, the value of the input parameter
is frozen in the parameter-controlled processing mode, after the cam generator is started
and is subtracted from the input parameters during the processing period. It is ensured,
that the cam is processed with the first index by starting at the beginning.
Interpolation
If processing is parameter-controlled and if there is a time control with a virtual master
axis, then interpolation can be executed between the table entries. It is possible to select
between a linear and a square interpolation. These settings are made in
Interpolation is not possible in mode "Time control" via the table index.
Interpolation can be executed in 256 steps between two supporting points.
m
Time control with a virtual master axis
Interpolation between the single table entries is executed at time control via the virtual
master axis with the actual position of the virtual master axis
. The table in-
dices, between which the virtual master axis is positioned, are defined from the virtual
master and are interpolated between both of these table entries, accordingly.
m
Parameter-controlled processing
n
Input parameters "float"
At an active interpolation, the integer components of the input parameters define the
valid table index. The decimal position components define the interpolation point be-
tween the valid and the next table entry.
Example:
Count supporting points
= 128
Base value
= 0
Input parameter value = 29.8