Set Value Generators
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
434
4.6
159.2
Cam options
Settings of the different operating modes and functions of the cam generator.
3
Stops the processing at time-controlled processing. As soon as the bit is
reset, processing is started again at the same point (interrupt function).
0: Time-controlled processing is running
1: Time-controlled processing is stopped
4 … 6
Reserved
7
The actual valid cam is invalidated. There is no valid cam available in the
RAM of the controller.
0
1: The actual cam is deleted in the RAM
Bit no.
Meaning
Bit no.
Meaning
0
0: time-controlled processing
1: parameter-controlled processing
1
Time-controlled processing, only
0: time control via the table index
1: time control with virtual master axis
2
Time control with virtual master axis and parameter-controlled processing,
only
0: no interpolation
1: active interpolation
3
Time control with virtual master axis and parameter-controlled processing,
only
0: linear interpolation
1: square interpolation
4
0: specify cyclical offset manually
1: generate cyclical offset from the cam
5
0: processing one-time only
1: cyclical processing
6
0: real time mode
1: relative mode
7
Parameter-controlled processing, only
0: no auto offset
1: active auto offset