Management
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
356
4.5
108.8
Status dig. inputs drive manager
Display of the state of the digital inputs for drive control.
If the corresponding inputs in Parameters
ff DIy_Mode are not configured for
Ppulse enable (IF)/Quick Stop (SH)/Controller enable (RF), the bits in DI_StatusDrvCon-
trol will always be shown HIGH.
Exception for Pulse enable (PE):
Since for hardware reasons the Pulse enable inputs for the axes also act directly on the
power unit, the actual state of the Pulse enable inputs is always shown in DI_StatusDrv-
Control, regardless of DIy_Mode.
108.9
Parameter selection status bit 14
Selection of the parameter for the freely definable Status Bit 14 in the drive manager Sta-
tus Word
If at least one bit from the mask
is set in the selected parameter, Bit 14 in the
Status Word will be set.
When StatusB14_IdSelect = 0, the mapping for Bit 14 is switched off.
108.10
Bit pattern status bit 14
Mask for the freely definable Status Bit 14 in the drive manager Status Word
If at least one bit from the mask is set in the selected parameter
, Bit 14 in the
Status Word will be set.
Bit no.
Meaning
0
Pulse enable (IF)
0: Pulse enable input is inactive (pulses are inhibited at digital inputs (IF=0))
1: Pulse enable input is active (pulses are enabled at digital inputs (IF=1))
1
Quick Stop (SH)
0: Quick Stop input is active (Quick Stop request present, (SH=0))
1: Quick Stop input is inactive (Quick Stop request not present, (SH=1))
2
Controller Enable (RF)
0: Controller Enable not set (RF=0)
1: Controller Enable set (RF=1)
3
Error reset by digital input (edge controlled)
0, 1->0: No requirement for error reset
0->1: Errors should be reset
4
Drop-out delayed Quick Stop signal (see also delay time for Quick Stop
input
1: Quick Stop input is inactive or delay time is still running
0: Quick Stop input is active and delay time has elapsed
5…15
Reserved