![Baumuller b maXX BM2500 Скачать руководство пользователя страница 355](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400355.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
355
4
108.6
Drive status
This parameter displays the instantaneous state of the drive.
108.7
Comm. source
This parameter controls the access rights to Control Word 1.
The drive will only be controlled by the Pulse enable (IF), Quick Stop (SH) and Controller
Enable (RF) hardware signals if all the bits for motor control are cleared. Digital inputs
must be configured for these signals to do this (see Digital Inputs Parameter DIx_MODE
ff).
Regardless of the communications source:
m
The Pulse enable (IF) hardware signal must always be wired up.
m
If no inputs have been configured for Quick Stop or Controller Enable, the signals will
be interpreted as inactive or active so that the drive can be enabled (see also Param-
eter
DI_StatusDrvControl (Status digital inputs drive manager) in this regard)
Value
Meaning
0
Not ready to switch on
1
Switch on inhibit
2
Ready to switch on
3
Switched on
4
Operation enabled
5
Operation inhibit active
6
Shut-down active
7
Quick Stop active
14
Error response active
15
Error
Bit no.
Meaning
0
1: Motor control via ProDrive/ Fieldbus
15 ... 1
Reserved
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......