States of the Device Control System
n
NOT READY TO SWITCH ON
m
The electronics are supplied with power
m
Initialization is running
m
The drive function is inhibited
m
The operationally ready relay is OFF (drive is not operationally ready)
n
SWITCH-ON INHIBIT
m
Software/hardware initialization is complete
m
The parameters for the application can be changed
m
The drive function is inhibited
m
Switch-on is inhibited
m
The operationally ready relay is ON (drive is operationally ready)
n
READY TO SWITCH ON
m
The parameters for the application can be changed
m
The drive function is inhibited
m
Switch-on is enabled
m
The operationally ready relay is ON (drive is operationally ready)
n
SWITCHED ON
m
The parameters for the application can be changed
m
The drive function is inhibited
m
Power unit is operationally ready, DC link voltage / mains voltage is present (de-
pending on the parameterization)
m
The operationally ready relay is ON (drive is operationally ready)
n
OPERATION ENABLED
m
The parameters for the application can be changed
m
Drive function is enabled
m
The operationally ready relay is ON (drive is operationally ready)
n
OPERATION INHIBIT ACTIVE
m
The parameters for the application can be changed
m
Drive function is enabled
m
"Inhibit Operation" command is executed
m
The operationally ready relay is ON (drive is operationally ready)