4.4.10 Digital Inputs
The controller has four digital inputs. The inputs DI1 and DI2 are quick and are suitable
for the touch probes.
Any function can be selected for the inputs DI1 to DI3.
The function "Pulse enable" is on digital input DI4. DI4 cannot be inverted.
When using the quick stop, the assignment "Quick stop - DI1" is recommended.
Only ONE FUNCTION per input may be selected. With one function, one input linking per
input can be used at the same time (see also Operating Mode for Digital Input 1,
Normally the inputs are invertible. An inversion of the input does not effect on the "Pulse
enable" function and "Measuring probe" function. Only the hardware status of the respec-
tive input is significant for these functions (for this see
4.4.10.1 ProDrive Digital Inputs
Figure 93:
ProDrive Digital inputs
Function
DI1
DI2
DI3
DI4
Pulse enable
HW
Measuring probe
HW
HW
Error reset
X
X
X
Quick stop
X
X
X
Controller enable
X
X
X
Neg. HW limit switch
X
X
X
Pos. HW limit switch
X
X
X
Zero-point-sw
X
X
X
Reset time stamp
X
X
X
X
Brake feedback
X
X
X