4.4.7.1 ProDrive Autotuning of the Current controller
Figure 90:
ProDrive Autotuning of the Current Controller
4.4.7.2 Parameter overview
Functional block:
Autotuning of the Current Controller [123]
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
123.1
Mode
UDINT
0
0xffffffff
1
1:1
X
123.2
Status
UDINT
0
22
0
1:1
X
123.4
Display max. current
FLOAT
0
10000
0.00 A
1:1
X
123.6
Stator resistance measured
FLOAT
0.0
100
1.7
Ohm
1:1
X
123.7
Inductance measured
FLOAT
0.0
10000
6.4
mH
1:1
X
123.8
Result current controller Kp
FLOAT
0.0
1000
0.0
V/A
1:1
X
123.9
Result current controller Tn
FLOAT
0.0
1000
0.0
ms
1:1
X
123.10
Parameters takeover
DINT
0
15
0
1:1
X