Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
145
4
with:
I
sq M-limit
Torque current limit from torque limit
138.22
, in A
M
limit
Torque limit symmetric,
138.22
, in Nm
Flux
set
Magnetic flux set value in %
Kt Kt
=
Kt
corr
· Kt factor, in Nm/A
Kt
corr
Kt correction factor,
Kt factor
Motor Kt in Nm/A: "Kt factor",
Furthermore, other settable torque limits are available that result from the setting of the
torque current limit (
,
). Furthermore, other
torque current limits are available
and
the torque due to a breakdown torque or an U
dc
actual value. The torque can be disabled
due to a power failure refer to
bit 1).
The strongest limit is effective.
The exact correlation between the torque current and the torque is shown in the torque
monitoring (
138.24
Indication threshold torque
If the absolute value of the effective torque (
) exceeds the value of the torque
threshold, bit 0 in parameter Status current limitation (
) is set.
138.25
Status current limitation
Status parameter for the functional block current limitation
I
sq M-limit
M
limit
Kt
Flux
set
100
-----------------
----------------------------
=
Bit no.
Meaning
0
Indicates whether the absolute value of the effective torque (
greater or less than the set torque threshold (
)
0: The torque is less than the torque threshold
1: Torque threshold exceeded
31 ... 1
Reserved
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......