4.4
Other torque current limits are available as well:
,
and the
torque current limit generated by the torque limit
Other torque current limits are available, as well:
. Furthermore, the motor-operated torque current can be disabled due to power
failure (refer to
bit 1).
The strongest limit is effective. The definite upper and lower torque current limit are dis-
played in
In comparison with the symmetrical, cyclic torque current limit (
138.15
can not be written cyclical. However, it can be saved and is subject to the hysteresis
(
) when defining the quadrant.
Standardization:
100%
=
138.16
Speed threshold for breakdown torque limit
Operating speed n
K
that limits the maximum torque current by the breakdown limit l
k,Max
instead of the set max. torque current, l
sq,Max
as follows:
See
on page 470 and see also Factor for breakdown torque
.
138.17
Factor for breakdown torque
This factor is used to adjust the Ud voltage limit at the breakdown torque that is used to
calculate the "lsq limit breakdown torque" (
) and the threshold speed break-
down torque limit (
NOTE!
The parameter must continuously be understood as the percentage set of the "Max.
torque current"
. The parameter can be entered and displayed in ampere (this
is demanded as an auxiliary setting) at ProDrive. The value which was entered in am-
pere however can change during the operation because the reference value can
change because of the field weakening or the external total current limit. See param-
eters
and
I
K Max
n
K
n
act
---------
I
sq Max
=
NOTE!
As the "Max. torque current"
dependent of the field weakening or the external
total current limit can change in the operating process, the threshold speed value of
138.16
can change, as well. Refer to the parameters
and
.