Electrical data
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
Baumüller Nürnberg GmbH
74
3.4
3.4.3
Output frequency-dependent current derating
All Baumüller devices have been developed so that the rated output current, as stated,
are only continuously permitted (i. e. in S1 operation) with an electrical output frequency
of 15 Hz or higher. If the static inverter output frequency is smaller than 15 Hz and the
frequency is between 0 and 15 Hz for more than 5 seconds, then the continuously per-
missible output current must be reduced according to the following characteristic curve.
These are affected, for example, but not exclusively:
n
Applications with rpm control but without positioning, or
n
Applications in which a current is required to assure a torque / a force at standstill or
n
Applications in which blocking of the mechanical parts can occur, e.g. when starting up
cold extruders.
Thus, typically, the following applications are not affected:
n
Generally, typical positioning applications
n
Applications with motors that use a service brake when at standstill.
n
Applications in which the higher-level control unit has standstill and blocking monitor-
ing.
Insofar as the derating range has been cycled through with sufficient speed, the applica-
tion of I
rated
is permitted. Here, cycled through with sufficient speed means that the fre-
quency change corresponds to
15 Hz/s.
Derating of the motor-side inverter output current I with respect to the rated output current
I
rated
as a function of the static inverter output frequency f.
I
I
rated
Static inverter output frequency f
Figure 30:
Derating with a static inverter frequency < 15 Hz
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......