BM5030 with Safety Function
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
313
B
C.6.2 Connections front side BM5030 with safety function
X1
Digital inputs / outputs
BM5030-XX2X-...
X1
Digital inputs/outputs
1
:M24V
2:
Inhibit input
3:
Reserved
4
: Reset
5:
Error
6:
Ready-to-operate
Figure 131:
Connection X1 front side BM5030 with safety function
Pin assignment
Pin
No.
Assignment
1
Dig. input/output GND 24 V
2
Digital input
Inhibit input
1)
BM5030-XXX
0
input is high active,
expects
NO contact
BM5030-XXX
1
input is low active,
expects
NC contact
3
Digital input
Reserved
4
Digital input
Reset
5
Digital output
Error
6
Digital output
Ready-to-operate
Input current per input
7 mA
Input level
High (12 … 28 V)
Output current per output
500 mA
Output level
High (12 … 28 V)
Содержание b maXX 5000
Страница 101: ...Design and Operation Instruction handbook b maXX 5000 Document No 5 09021 16 101 of 328 4 ...
Страница 220: ...Fieldbus communication Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 220 of 328 8 4 ...
Страница 240: ...Error handling Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 240 of 328 10 4 ...
Страница 298: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 298 of 328 A ...
Страница 299: ...299 of 328 Operation Manual b maXX 5000 Document no 5 09021 16 APPENDIX B DECLARATION OF CONFORMITY ...
Страница 324: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 324 of 328 Table of Figures ...
Страница 328: ...Instruction handbook b maXX 5000 Document No 5 09021 16 Baumüller Nürnberg GmbH 328 of 328 Notes ...
Страница 329: ......