Cabling
Instruction handbook
b maXX
5800
Document No. 5.16027.04
Baumüller Nürnberg GmbH
146
11.1
11.1.6.1 Connecting cable for Resolver
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1
Utilize the following materials:
m
Cable: Li9YC 1x2x0.25-Li9Y 2x2x0,25-Li9Y C11Y 1x2x0.34GN.
m
High-density D-sub connector: 26-pin, male
m
Round connector: 12-pin, female (e.g. from Interconnectron)
2
Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 48:
Connecting cable for resolver
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not operable and could lead to de-
fects, both in the encoder module and the encoder!