19
Instruction handbook
b maXX
(BM4-F-)DIO/FIO-XX (Digital IO module)
Document No. 5.01046.06
3
T
ECHNICAL
D
ATA
3.1
Electrical data
1)
Unlike DIO/FIO-01 inside DIO/FIO-11 the contact „ground external“ is
not
connected to PE.
2)
On tripping, there appears an error message on the controller.
3)
Limit the current to 2.5 A. (Due to this also UL 508 C with a maximum current of 4 A will be considered.)
DIO-01 / DIO-11
1)
FIO-01 / FIO-11
1)
Supply voltage
24 V (19 to 28 V)
3)
Current consumption (24 V)
max. 2.0 A
Current consumption (internal)
max. 50 mA
Number of inputs
4
Evaluation of inputs
edges (2 inputs can be used for writing on one parameter)
Number of IO-linking groups input
4
Max. input current
2 mA
5 mA
(Typical) transit time delay, input side
4 ms
10 µs
Digital input voltage
0 (LOW) = 0 to 5 V;
1 (HIGH) = 12 to 28 V
Number of outputs
4
Number of IO-linking groups output
4
Max. output current
0,5 A
Short circuit proof at outputs
yes, limited by current with tripping