P1212
If the output current exceeds the setting specified in
when the drive is operat-
ing, the drive will decrease its output frequency to prevent the motor stall. If the output
current is lower than the setting specified in
, the drive will accelerate again to
catch up with the set frequency command value.
Figure 55:
Over-current stall prevention during operation
P1212
Überstrom Abschaltschutz während Betrieb
0 to 250 %
EE
Over-current stall prevention level during oper-
ation
170 %
STOP
BM_u_OverCurrentStallPreventionLevelOper
1:1
Value
Meaning
0
Disabled
20 to 250 %
Enabled