PA210
16
www.baumer.com
4 Operating mode – programming mode
Operating mode
The device is automatically on the operating mode after the voltage
supply has been turned on.
Programing mode
Device parameterization is by three soft keys located below the front
panel (see below).
Keypad
(view from below)
Key functions
Key
Access programming level and select programming line.
Key
Select functionality or decade in the programming line. The selected
digit is flashing.
Key
For incrementing of selected decades.
Programming
1. Press , display will switch to [Pro] which means access to
programming level. Another press will make the display skip to
first programming line dSP (option input signal).
2. Proceed with line parameterization using keys , and .
3. Pressing key after the last programming line will automatically
save the parameters, which is briefly signaled by [Stor] prior to
automatically exiting the programming level.
4. Programming access can be disabled at programming level, in
this case programming lines will be read only. The device will
signal any programming lock by [dAtA] instead of [Pro] upon
access.