![Baumer OM70 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/baumer/om70/om70_operating-instructions-manual_2710818034.webp)
en_BA_OM70_multi-spot.docx
34/60
Baumer Electric AG
04.01.2021 14:26/tof V1.2 ANW_81156398
Frauenfeld, Switzerland
6
Function and definition
6.1
Sensors data sheet
General data
OM70 multi-spot
11155463
OM70-11155463
OM70 multi-spot
11112069
OM70-11112069
Function
Distance
Distance
Function: FIELD OF VIEW
Yes
Yes
Measuring range (distance)
100…150 mm
100…500 mm
Start of measuring range Sdc
100
100
End of measuring range Sde
150
500
Measuring range (width)
48…72 mm
13
…66 mm
Measuring field width right @ Sde
+36 mm
+33 mm
Measuring field width left @ Sde
-36 mm
-33 mm
Blind region
0…100 mm
0…100 mm
Measuring frequency
- OBJECT bright (approx. 90% Refl.)
- OBJECT dark (approx. 6% Refl.)
244
…570 Hz
192
…342 Hz
440
…1540 Hz
340
…770 Hz
Response time
- OBJECT bright (approx. 90% Refl.)
- OBJECT dark (approx. 6% Refl.)
3.5
…8.2 ms
5.8…10.4 ms
1.3…4.5 ms
2.6
…5.8 ms
Resolution AVG DIST
(max. measuring field width)
8…16 μm
345
(Without filter)
4…8 μm
(With filter Precision high)
2…4 μm
(With filter Precision very high)
15
…55 μm
(Without filter)
8
…28 μm
(With filter Precision high)
4
…25 μm
(With filter Precision very high)
Resolution MIN / MAX DIST
23…48 μm
12…24 μm
(With filter Precision high)
6…12 μm
(With filter Precision very high)
70…150 μm
45…75 μm
(With filter Precision high)
25…45 μm
(With filter Precision very high)
Repeatability AVG DIST
(max. measuring field width)
8
μm
(Without filter)
4
μm
2
μm
(With filter Precision very high)
10…40 μm
(Without filter)
5…25 μm
(With filter Precision high)
4…20 μm
(With filter Precision very high)
Repeatability MIN / MAX DIST
16
μm
8
μm
(With filter Precision high)
4
μm
(With filter Precision very high)
30…90 μm
20…70 μm
(With filter Precision high)
15…60 μm
(With filter Precision very high)
Linearity error
± 20
μm
± 100
μm
Linearity error overall
± 40
μm (0.08% measuring range)
± 420
μm (0.11% measuring range)
Temperature drift
± 0.04% Sde/K
± 0.04% Sde/K
PRECISION filter values:
Standard
High
Very High
Median Average
Off Off
3 Off
3 16
Median Average
Off Off
3 Off
3 16
Smallest detectable object
0.7…1.1 mm
1…5 mm
Laser class
1
2
Max. reference surface unevenness (rms)
0.25 mm
1 mm
Min. reference surface length
24 mm
12 mm
LIVE MONITOR:
Minimum object height
Minimum object width
4 mm
4 mm
10 mm
12 mm
1
Measuring rate depends on the measuring field (distance). Min value: Maximum measuring field; Max. Value: 20% of the measurement
field
2
Measuring rate depends on the measuring field (width)
3
Measurement with Baumer standardized measuring equipment and targets depending on measuring range (distance)
4
Measurement on 90% remission (white)
5
Measurement with measuring type average
6
With active filtering
7
Measuring range (distance) 100…112.5 mm
8
Measuring range (distance) 100…200 mm
Содержание OM70